adspace
A DP transmitter is used to measure the level of an open tank.
The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator.
If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
Answer Posted / Sonu Singh
To wire a DP transmitter and control valve with a HART communicator, follow these steps:
1. Connect the pressure tap from the bottom of the open tank to the DP transmitter's input.
2. Connect the transmitter output to the control valve input.
3. Wire the HART communicator to the DP transmitter according to the manufacturer's instructions.
4. Configure the transmitter and valve using the HART communicator, setting up the desired proportional relationship between tank level and control valve opening.
5. To find the %opening of the control valve at 60% level of the tank, we can use the following formula:n Control Valve Opening = (Tank Level - Tank Minimum Level) / (Tank Maximum Level - Tank Minimum Level) * (Valve Maximum Opening - Valve Minimum Opening) + Valve Minimum Opening.nAssuming the tank has a maximum level of 100%, a minimum level of 10%, and the valve opens from 0% to 100% as the tank level changes, we can calculate the control valve opening at 60% level:n Control Valve Opening = (60 - 10) / (100 - 10) * (100 - 0) + 0 = 40%
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...
send me last 5 years questions asked in rrb chennai, for section engineer
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
What is the Working principle of Dozing valve?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
this site is owned by an nonsense
sir, give me placement papers and interview quistion of birla group company of copper.
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
give me all the details about the interview and which type of question being asked
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
Questions on flow meters,few questions on HART protocol,
use of split range ? where it is used ? in which control loop it is used ?
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.