adspace
checking procedure of capacitor based motors.used in fans etc?
Answer Posted / Aadesh Kumar Singh
Capacitor-start induction motor (CSIM) is a common type of capacitor-based motor used in fans and other appliances. Here's how to check it:
1. Disconnect the power supply.
2. Remove the capacitor from the motor, ensuring safety measures are followed.
3. Use a multimeter to measure the voltage rating of the capacitor, which is usually printed on the capacitor itself.
4. Set your multimeter to the capacitance setting and connect it across the terminals of the capacitor.
5. Read the value displayed by the multimeter, which should match the voltage rating if the capacitor is good.
6. If the measured value is significantly different from the rated value or if there is no reading at all, the capacitor needs to be replaced.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
I NEED RRB SYLABUS FOR JE ELECTRICAL ,PLEASE SEND TO MY E- MAIL ID joo28_eee@yahoo.co.in
1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends
sir, I am from EEE branch.On feb 17 iam going to write an Exam for hindustan petrolium corporation Ltd.So plz send me the written exam pattern/Q's/interview questions.please mail to eee_dharmendra@yahoo.com
hi this is hema, r there any books in particular for the preparation of the APPSC-A.E.E(electrical), if so please mail me the names ... thank u .
i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.
hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
two way ckt diagram can be drawn by how many ways? give diagram
If a current -8+6sin6t is flowing three ammeter, one is a centre zero PMMC meter, one is true rms meter and one is moving iron meter. What are the reading of these three meter respectively?
Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?
Define the overload capacity of the motor?
What will be result if we connect LT votage to the terminal of HT motor?
How to calculate VCB rating for 33KV ,25 MW Power line?
Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.
Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.