adspace


what is the purpose of slope in the differential relay?why
we are using two slope?but in busbar differential we are
using only one slope.why?

Answer Posted / Tripti Agarwal

The purpose of slopes (Differential and Restraining) in a differential relay is to define the trip curve, which determines when the relay will trip based on phase-to-phase unbalances. The Differential slope detects unbalances caused by faults or load imbalances, while the Restraining slope helps prevent false trips due to normal load fluctuations and other harmonic distortions.nIn busbar differential relays, only one slope is used because busbars have simpler electrical configurations compared to three-phase systems. A single slope provides an appropriate trip curve for the busbar system without requiring separate restraining and differential slopes.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????

2099


Draw a SLD of DG distribution up to main LT panel?

9586


what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer

3062


what will happen if synchronous machine rotor fed from single phase ac supply 

1820


send me any model test paper of clerical post of state bank of india.......

1935


Why squirrel cage motor can only use with low starting loads ?

2166


Enlist four components of electrive drives.

1910


Please send 110 kv sb station full single line drawing(sld)

2543


please send me latest & previous years question papers for IOCL Technical level questions

1953


sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com

1882


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2410


can you send me the placement papers of electrical engg. from companis like NTPC,DRDO,IOCL,HPCL,BPCL etc.?If,plz send as soon as possible.Thanks.

2222


What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?

1645


i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.

2000


Can Anyone Answer anyone of these ? Q1) why direct SOLUTION of Load Flow Studies in Not Possile ? Q2)Why majority of Buses in power system are load buses Q3)Why one of the buses in Power system is taken as reference bus (slack or swing) Bus ? Q4)Bus Admittance Matrix is a sparce (means it contains some zero elements ) matrix , give reason

2024