i am going to correct power factor of 1600kw induction
motor,when i calculate capacitance of capacitor it is three
time more in star connection than delta. if motor is star
connected which connection i shall adopt for capacitors and
reason for adopt this connection
Answer Posted / Vijayendra Nath Mishra
Since the induction motor is connected in a star configuration, you should connect the capacitor in a star connection as well. The reason for this is phase matching: when both the motor and capacitor are connected in the same configuration (star or delta), they have identical phases, which helps to correct the power factor more effectively.nnIn a star-star connection, the voltage across each phase of the capacitor will be equal to line voltage. The total capacitance required for a star-connected motor can be calculated using the following formula:nnCtotal = (3 * Cperphase) / (1 + squareroot(3))nwhere Cperphase is the capacitance per phase in delta configuration.n
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Enlist four components of electrive drives.
TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.
HAI SENT HPCL APTITUDE QUESTION PAPER, MY EMAIL ID IS angus_eee04@rediffmail.com,angus_eee04@yahoo.com
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com
what will happen if synchronous machine rotor fed from single phase ac supply
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?
hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV
what is the condition for YnD11
Draw the line diagram of diffretial relay connected to transformer?