In one plant id fan and fd fan are used for boiler. boiler is used to heat water after some days they install one tank to heat water by hot flue gases coming out from boiler and then hot flue gases are used to heat the air coming from fd fan before leaving out from chimney . but hot flue gases are not coming out from id fan what might be the reason?
Answer Posted / mayur mukaty
APH outer air is not more than 140 c and less than 130 c because of Sulphur due point.if APH efficiency goes down due to Soots deposit APH boiler outlet temp goes Increase on other side failure of Design or High CV fual feed to boiler also raised outlet temp. So that management decide for Recover heat by Heating of feed water that is thumb rule when you increase 3 c of feed water temp 1% increase Boiler efficiency. When you calculate Money terms you save lots of money
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
By any way can we increase the B check hours from 300 to 500
what is the basic use of power plant in equipment
what is the trip circuit supervision in an electrical meaning?
How do you consider that you can improve and what assistance do you need to achieve this
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
Why superheated are started before I'd and rd fan?
procedure of how to generate power in solar plant.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
What is difference between secondary Air & Tertiary Air and Their use.?
why do you consider yourself a suitable candidate for this position
operation
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon