Answer Posted / ankit desai
P&ID is Piping & Instrumentation diagram. P&ID will help for better understanding of Piping & Instrument of Plant or area. It give basic idea about plant & its equipment & also give idea of Closed loop & open loop.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is instrumentation measurement?
how to turbine speed measurement?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
What are the interlocks we have to check during the start up of LP/HP compressor?
you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.
for oil & gas industries which zone is normally preferred? why? give its example?
Explain operation of Haskel pump.
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
How to Calibrate Ultrasonic Level Transmitter in field
my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
why we us isolation barrier in hazardous area how it works to protect the area and please clarify its current flow.
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.
which type of zones used for boiler? & why ?
Is there any relation between Artificial Intelligence and Instrumentation?