What is the limit for friability of tablets?
Answer Posted / suhel patel
Hii Frnds,
physical strength
or tablet breaking force for compressed, uncoated tablets.
Tablet Friability Apparatus is used for the test. Remove
any loose dust from the tablets and accurately weigh 10
tablets. They are placed in the drum which rotates at 25±1
rpm. Rotate the drum 100 times, and remove the tablets.
The sample fails the test, if any of the 10 tablets
cracked, cleaved, or broken is present. If the weight loss
is more than 1.0%, the test is repeated for twice and the
mean of three tests is calculated. The mean not more than
1.0% is considered acceptable.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How we define validity of any Reagent , Indicator and Volumetric Solutions
Why we use 10 tablets for the analysis of cu test?
HI, I srinivas , was shortlisted for interview of Ph.D. PROGRAMMES FOR ACADEMIC SESSION 2012, I have interview on 17-nov-2011. Sir can you tell me about interview, how to prepare for it. How it will be? It's my first interview sir, i don't know how to face it. Kindly help me sir, Thanking yoU,
Why should we not dispatch the reprocess material to export?
What is pooled sample and why it is required in dissolution test?
What is the Disintegration time for Hard gelatin Capsule in USP?
In dissolution test why sample is withdrawn from top of the paddle and not less than 1 cm away from wall?
What is the relative response factor in related substances?
WHEN WILL GUJRAT GOVERNMENT ANNOUNCES DRUG INSPECTOR POSTS AND WHEN WILL BE THE EXAM CONDUCTED? INFORM ME AND ALSO EAMINATION DATE
which is the best pharma company u think
What steps would you take to ensure responsible prescribing and prevent overuse or misuse of Alprazolam in your patients?
HOW TO PERFORM SATURATION SOLUBILITY IN DISSOLUTION METHOD DEVELOPMENT?
Why do not dry vanillin befour MR CALIBRATION
plzzz..send me the pevious papers of drug inspector for uppsc....i.l b highly oblige
If calibration of 12 bowl dissolution apparatus does not meets single stage procedure, how can you precede calibration?