why insulation cost is more in underground cable than in
overhead line?
Answer Posted / sk.azhar.m
An underground line is fill in the earth and when if the leakage current will flo in the erth the current rating will very high in the cable that is very dangerous for human and other and in the the overhead line the air is not good conductor of electricity while an underground line is more insulation than overhead line for this reason the insulation cost is more in underground system
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
sir, i'm preparing for hpcl exam officer trainee pls tell me how the exam ques paper pls pls
The electromagnetic torque developed is proportional to what in a D.C series motor?
what is active power & reactive power?
what is the terminal voltage of dc series generator running at rated speed at no load?
what is difference between cpp electrical system and refinery electrical system
what is working process of star delta controlling circuit ?
how to increase or decrease speed in DC shunt motor by DC convertor
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.
plz tel me syllabus and exam date 4 jr executive engg (electrical)
difference between the applicability of nortons and thevenin theorem
what is magnetizing and demagnetizing current in generator and motor?
I am going to appear RRB Sr. Section Engineer Exam, Electrical. Can you send me previous year questions of RRB Electrical engineer. specially Section Engineer questions. my email id is likerahulworld@gmail.com
A low wet bulb temperature indicates
The D.C. spark test is applicable to single conductor cable & assemblies of insulated single conductor cables without insulation shield,metallic sheath or metalic armor?