Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In which principle Woodward Governor 505 work in power
plant? What are the input of Woodward governor 505

Answer Posted / praveen kumar

Governor input is RPM....and based on setpoint it give 20-200ma to servo actuator, it increase actuator open or closing based on the setpoint and process variable(rpm) errors...its a simple controller oly...but the output range was changed....

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we take %i0.0 as input for twido plc

2178


my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

2279


can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.

2449


Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor

2144


i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1923


Where is wet leg is used?

1064


How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?

2347


what is stroke check for field instument transmetter's & AOV's

2202


we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks

2183


What is the Working principle of Dozing valve?

2217


What is zero elevation and zero suppression?

2176


please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?

2248


WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN

1994


What is mean by analytical instrumentation?

1820


what is wave length were using ?

1903