Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is GIS Substation and how it operate? where these type
of substation installed?

Answer Posted / sumit yogi

The GIS is also known as Gas Insulated Substation.

In gas insulated substation sf6 gas superior dielectric properties used at moderate pressure for phase to phase and phase to ground insulation.

It is enclosed in ground metallic housing.

It is compact and multi-component assembly.

In this sf6 gas is the primary insulating medium.

Various equipment's housed in metal enclosed modules filled with sf6 gas.

It is preferred for High Voltage ratings.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why burdens of VTs is more than CTs?

1783


i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.

1785


Make a list observation on Transformer?

2424


battery capacity use of made?

2538


what is protection class current transformer.

4287


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1921


what is the IPC ? & what the uses ?

1487


how to prepare the technical test

2081


A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?

1977


Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

1607


how to calculate current and voltage in a same circuit?

2212


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1914


how to operate and maintenance of 1500 kva diesel generator set

1805


can we use ZNyn11 transformer instead of Dyn11 transformer in distribution for effectively eliminating harmonics from the industrial loads.

5019


What are the uses of lead compensator?

1175