Our 8mw steam turbine (condensing cum extraction) exhaust steam temperature is high even after taken it in hogger why

Answer Posted / anup sharma

Your steam turbine is extraction cum condensing turbine, high exhaust temperature may result either
Turbine is running at part load, extraction valve is minimum open (High extraction steam is being delivered) thereby lesser amount of steam is entering in to lower pressure section of steam turbine, which may increase the temperature of exhaust steam due to churnning effect, It is also known as windage, Lower the extraction, and see for change,
or
Check fouling of condenser tubes

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is natural frequency of turbine shaft .

1713


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

2969


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1421


what does mean by kva rating

992


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

1821






im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1467


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1273


what is the meaning of SST300 V56A in SIEMENS turbine

3875


operation

1365


explain how the third harmonic content of the magnetising current affects transformer design

2764


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1225


How We Calibrate the vaccum transmitter?

1462


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

509


what's the moog valve

1044


what is restricted earth fault explain in details

1622