Question 102 - (a) As an approximation, let v = Zc / 137 where v is the radial velocity for 1 s electron of an element, c is the speed of light, Z is the atomic number. For gold with Z = 79, find the radial velocity of its 1 s electron, in term of c and percentage of the speed of light. (b) As an approximation, let A x A = 1 - Z x Z / 18769 where A is the ratio of the relativistic and non-relativistic Bohr radius. Find the value of A.
Answer Posted / kangchuentat
Answer 102 - (a) Approximately v = Zc / 137 = (79 / 137) c = 0.5766 c or 57.66 % of the speed of light. (b) Approximately A x A = 1 - Z x Z / 18769 = 1 - 79 x 79 / 18769 = 0.667 then A = 0.817. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the frequently asked technical questions in chemical engineering during PI?
Where the Induced draft, forced draft & balanced draft furnace are to be used? Selection of furnaces are based on which criteria?
What is the significance of the minimum flow required by a pump?
Is there a quick rule-of-thumb to estimate a gas side heat-transfer rate inside the tubes of a shell and tube heat exchanger?
What are the problems that are associated with the expansion joints?
Dear guys we adding hypo at climax plant and that water is inlet to DM plant so with hypo water that can affect my resins of cation and anion. if it is affect life of my anion and cation so what kind of steps should be take.
What is the maximum recommend pipe velocity for dry and wet gases?
Explain how does a tank-blanketing valve operate?
based on percentage problems
How can metals be removed from aqueous waste streams?
Why is double the amount of gas collected in one of the test tubes in electrolysis of water than th amount collected in the other? Name this gas?
what is the hearth and arch pressure in furnace?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
Oil and fat containing food items are flushed with nitrogen. Why?
Explain what type of pump may be appropriate for a liquid near saturation, a low flow rate, and very limited npsha (net positive suction head available)?