Describe how to calibrate various types of instruments and
transmitters using ISA industrial consensus standard
techniques.
Answer Posted / jadhavamit
Calibration of instruments are carried out under master equipment,they are calibrated under the "National Instrumentation Laboratory".
I can not tell u about the detail because it is under rule But i will explain it with example:
To calibrate a temperature Gauge-
The master equipment use is "Fluidless temperature Calibrate".
it work With out fuel so it is called Fluidless Temperature Calibrator the only thing u have to do is Put the End nod into the master equipment and initially set the temp. to 0degree cent. and step up to 30degree cent. with this see the reading proportionally in the Gauge no need to calibrate if it give +-0.2 reading. if it give deviation of +-5 then adjust the span and zero to set point result we been seen these is the method of calibration of temperature gauge.
Other example of master equipment are microprocessor based pressure calibrator,Macloid gauge etc.
Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
components of control circuit belongs to control valve
selection criteria of control valve? and selection criteria of actuator explain in brief?
IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
what is diffrance between FF & SMART, explain with difination
In dcs panel we are using diff type of modules ?what is module ? what is the use of modules ?diff type of module?
What are primary elements of measuring pressure?
please send the drdo exam paper
HOW TO CHOOSE FREAQUENCY IN FMCW TYPE RADAR INSTRUMENTS. DESIGN BASIS OR DESIGN CALCULATONS ?
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.
How process line mpm calculation is done?
where proximity sensor installed on tank in loading arm application
what is sliding spool valves?
How to do gas analysers calibration in AUTO and Manually by using zero and span gas?
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.