Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do select 11000v rubber mat even we use only 415Volts

Answer Posted / k.prakashchandra

It is thick ,heavy and safer .There may be 11KV indoor breakers also .

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the function of attenuator in cro?

1197


what is the difference between general inverter and solor inverter clerly explain plz

2097


sir plz send some previous year questions of jspl.

1933


Why do we need a separate control desk & PLC control panel in Boiler plant or coal handling plant? Can we provide cost effective Control desk cum PLC panel. Is there is an specific need for control desk.. kindly advice.

2364


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1945


What do you understand by avr?

1053


mccb service sittings be done?

1807


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

1257


why three phase capacitor takes unbalanced current in capacitor bank?

1490


If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.

6120


What is the difference between earthing,ground&nutral?

6677


why swityard is necessrry requirement in any bis power distributin systems?

2374


WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?

2221


Why back emf used for a dc motor? Highlight its significance.

1194


technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"

1984