Answer Posted / shami thakur
Recovery factor mostly used in cleaning validation it established during validation of cleaning method the known concentration of active spread in steel plate and with the help of swab recovery are performed for eg. 85% recovery are achieve with swab
So recovery factor is 100/85=1.18
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
what is the calculation for getting the tablet weight and the punch size, Eg..if there is a 8/32 punch then how to measure tablet weight????
What is the difference between uniformity of content and content uniformity as official test for all tablets?
What are the advantages and disadvantages of working for a small & big pharmaceutical company?
when will be the drug inspector notification will be anounced.what are the educational requirements...
what are all the parameters to be considered while applying bracketing and matrixing?where and all it is applicable?
What is the difference between Analytical method validation and Analytical method transfer?
Alprazolam has the potential for misuse and addiction. How would you approach prescribing Alprazolam to a patient with a history of substance abuse?
Why we are using propyl parabben in methanol in calibration of hplc for GPV test??
principle of dissolution
What is the Disintegration time for Hard gelatin Capsule in USP?
how quantitative stability is done
What is the difference of vacuum pressure and vapor pressure?
besides Signal & noise ratio how calculating LOD & LOQ?
How to select HPLC column for a particular product?
How we define validity of any Reagent , Indicator and Volumetric Solutions