How do you calibration D.P transmitter? ?
Answer Posted / santosh kumar
High side presser and low side atmosphere then callibeat transmitter.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Explain the use of hair spring in the pressure gauge.
what is scale factor of proximitor & unit of the vibration.
There are many type of control cable like pair,core,tried, What are defination each one
why using negative supply for bentley nevada vibration system ?
give some question relative instrument fitter?
why we are not using the turbine flow meter in the steam service?
To become an Instrument DESIGN engineer, is there any softwares or training to become Instrument Design engineer, plz suggest me, Iam very much interested in designing.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve
Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...
if my flow is 20000 m3/h than which range of DPT i have to use????
which type inter lock use in petrochemical refinery,and oil & gas?
how to work MIL contol valve posistioner ?
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.