Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In instrumentation standard we use 4 to 20ma for transmission , why cant we use 3 to 19ma ?

Answer Posted / naveen

Because of dead zero and live zero concept.
Dead Zero: this is basically derived from ohm's law
V=IxR. In electronics circuit minimum 250 ohm resistance is using. so V=Ix 250. Substitute I=0,1,2,3,4 after substitute 0 u will get V=0 ohm,(1;V=250 ohm,2;V=500 ohm,3;V=750 ohm,4;4=1000 ohm or 1 V) so when 4 ma is coming u will get 1 V,8 ma=2v,12 ma=3 V,16 ma=4v,etc..... u will get linearity .thats why 4 ma is choosing in all analogue value.
Live Zero: if tx is failure that time also zero value is coming.thats why 0 is not choosing

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

line up procedure for dp type flow transmitter?

1887


What is hp & mp seperator .& what is its working principle ?

2622


What is the difference between working pressure and calibration pressure of a control valve

3035


What is the meaning of wet leg

1227


How to Calibrate Level Troll in field

1388


what is the protection system in solar turbine compressor

2176


explain key exchanges in all security modes WPA,WPA2,TLS?

2023


What is the GK Value in Flowmeter?

3690


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1871


To become an Instrument DESIGN engineer, is there any softwares or training to become Instrument Design engineer, plz suggest me, Iam very much interested in designing.

3443


if my flow is 20000 m3/h than which range of DPT i have to use????

1829


What is the start up procedure of desalter

3670


Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?

1758


can you provide me full detail about instrumentation in ONGC??

2151


Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection

2005