Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Actually why the transformers ate rated in KVA.?

Answer Posted / pradyumna171

Transformer gives apparent power,it is the supply power to load and the power actually used by the load is the real power/true power/active power. Apparent power of 100 KVA has capacity to give 100 KW resistive load and for inductive load of o.8 pf it give 80 KW,and at 0.7 pf the same has capacity to give 70 KW . but the manufacturing company does not know which type of load to be connected across the transformer,therefore in simple we can say " DUE TO UNKNOWN POWER FACTOR THE TRANSFORMER ARE RATED IN KVA" and it is meaning less discuss about Iron loss & copper loss because the Inverted and UPS are rated in KVA but there is no iron loss & copper loss And in other hand in DC Generator there is Iron loss &copper loss but it is rated in KW not in KVA, because there is no angle between current and voltage(pf) in DC supply N.B transformer capacity -transformer iron loss & copper loss = transformer efficiency in KVA
PRADYUMNA CHANDRS PANDA
Mob No. 9437917849

Is This Answer Correct ?    22 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2303


why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

1935


Pl. give me checklist for installation & commissioning of machine tool.

2233


What is the difference between AC and DC injection methods for rotor earth fault protection

2149


A jet of fluid strikes a plate What was the force required to counter it?

1822


How grounding is different than earthings?

1117


why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?

3623


Give two basic speed control scheme of dc shunt motor?

1052


WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION

1911


what are the problems that generally occur in power flows??

3155


how to electrically make connection to ferroli GN2N?

1879


11000volt DG set carnt kaise banvay

1625


Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1709


What is the important precuations need tocarried out while working with Electrolite in Battery PM?

1844


For a stable system, where should the poles of a system be in a root loci plot?

1178