1 tr is equal to how many Kw .is there any specific formula
for this to get the result .
Answer Posted / david joson
The TR for the ACCU is determined by its efficicient Coefficient of regrigeration or the (COP) Coefficient of Performance. It ranges from 1.5 to 2 max value depending on its voltages. Thus 1TR=1x1.5x746=1119 watts or 1.5 hp
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.
typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?
HOW CAN I GET 5CORE HO7 CABLE SIZE IF I HAVE 1800A?
Hi Everyone ! My Name is Hakim ullah khan please i need formula of Cable Rating because i want to calculate by self without check any Table Chart... Thank you.....
The advantages of Magnetic flux leakage technique over Ultrasonic technique for non distructive testing of material.
if 6 earth pit value is 1.5 ohm then what should be the number of earth pit to make the value .8 ohm
What is the types of HT motor testing
how to calculate short circuit current for the busbar
Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
Will an earth leakage trip be activated if the component or wiring is faulty on low voltage equipment.Example An electrical Cat Scarer placed in the garden and water gets into the wiring.
how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?
What are the symptoms of a bad PG card of a drive (inverter) esp. of Yaskawa Ac Drives (inverters) G7 ?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
what is the safty of poly phase tranformer?