For 300MW and over a distance 250 km, what voltage be
selected? and no. of circuit?
Answer Posted / k.prakashchandra
It is better to have a gen station nearby or go in for HV DC transmission
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the mechanism of WTI
how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?
can you please send me the technical questions and aptitude questions of honeywell and jindal steel electrical engg. question paper my e-mail ID is(kkesavanraj@gmail.com)
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
Define liftable weight of a transformer? Does the total weight of transformer include oil weight?
why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points
what is the difference between elcb and rccb ?
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
What are the basic components of the feedback control system?
what is feeder bay?
List of equipments required foe industrial repair lab.
What happen in ups if phase reverse?
please send me last 5 year interview questions
in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?