why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupling alignment ?
Answer Posted / rayudu thota
While rotation high speed shaft of gear box will lift by low speed side shaft due to the load on high speed shaft
Then it will come in to centre line after rotation.
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
what is restricted earth fault explain in details
How We Calibrate the vaccum transmitter?
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
can dp type level transmitter work in under vaccum condition
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
what does mean by kva rating
LAPT working in alternator / generator
What is LB-SR.
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon