Single acting ON-OFF valve. it is air to open. when sov energized , valve will be open, so during that if air fail then what will be the condition of valve ( open or close ) ???

Answer Posted / kausar

If it has airlock then it will be remain same because at the time of pneumatic failure it locks the air automatically.generally now with control valve airlock,booster ,sov and air filter regulator are arranged in order to make the line safe

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi! i want to know about mpse exam.

1784


1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.

1885


hiii.... can any one provide me previous years question paper of hindustan petroleum for instrumentation engineering???

1520


If fire would be inside the plant which fire detector is to detected the fire.

1067


selection criteria of control valve? and selection criteria of actuator explain in brief?

3648






why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?

5881


What is the purpose of bypass valve across AS valve.

1654


give me all the details about the interview and which type of question being asked

1792


What is the GK Value in Flowmeter?

3045


Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection

1584


What is instrumentation instrumentation engineering?

632


what is your eligibility criteria for freashers?

1629


Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com

2696


How to Calibrate Ultrasonic flow Transmitter in Field

792


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

1952