Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1. If we apply dc supply to the
primary winding
of transformer it will be burnt out.
similarly dc
supply is given to field winding of
syn. motor
and armature winding of dc motor,
they are
safe. (Remember both windings
inductive nature) what is the reason
behind that?

Answer Posted / sourabh vishwakarma

because dc has no frequency so that it can't produced inductance than transformer get heated and burn but dc have megnatic proparty so that motor works in dc.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the site acceptance tests for power cables, DG Sets, LT panels & 30kVA UPS ?

2371


how solar power plant energy meter multiplication factor

2081


with 3 phase board on a 63 amp rcd is it ok to have 6 electrical showers 2 on each phase and what problems could happen

1807


How to synchronization will be done between two DGs ?

1750


Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

3330


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1858


What is the distance between each insulator in 33kv transformer and how can it calculate

2173


In a tap changing transformer where is the tap connected, is it connected in the primary side or secondary side?

1119


How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com

2097


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1860


while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?

1903


What was the Dg set radiator and lube oil temperatures trip in ACB

1805


how electrical earthing maintenance done in industry?

1600


All tape of electrical questions Answers tape of motor transformer e.o.t crane

2632


How to calculate VA rating for CT or PT or Control Transformer?