Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the advantage and disadvantage of billing in kwh
and kvah by electricity board .

Answer Posted / julio trujillo, pe

I thank Maurits Paath for the info on Malta, I didn't know they adopted the KVAh unit and now 2 countries are ahead on power metering.

It's interesting that we still refer as "poor PF" or "harmonics problem" when talking about load characteristics. We must change these perceptions, specially when metering is involved. These were problems when meters couldn't read them; as we already have meters that register KVAh then we can bill the whole energy use.

Of course, there's still an infrastructure issue because harmonics produce heat, vibration, and "noise". Also, large reactive loads produce power leakage towards earth. These must be dealt with, and billing for them will provide funding.

There's another issue; researching I found that meter companies have not reached a uniform method for KVA calculation or a direct means of measurment. Thus, there will be different readings between meter brands. Although the difference shouldn't be large, a standard should be established, and this will happen when demand for the product increases.

So, actual metering losses is solved with KVAh register adoption. Demand for these meters will push for a standard establishment. And new profits, along with client's request for lower bills, will provide for better infrastructure. This is progress.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If the line voltage is reduced to 75% of its rated value then by what percentage current will reduce ?? 75% 25% 50% no change and why ?

2203


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1948


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1674


How to measure the earth resistance value in a concrete pavement(flood light area)?

2228


what happen if the parallel generator phase angle shift by 1 degree in manual mode

2062


ht side line to earth voltage

1585


what is the function of anti pumping relays? what is KVAR? How it is generated in alternator? What is 3rd Harmonics? What is IDMT relay?

2319


How to check the thermocouple is correctly connected to cable for K type? (i,e positive pole is connected to non magnetic conductor and negative pole is connected to magnetic conductor)

1722


HOW TO WORK A VFD?SAY SIMPLE METHOD

4437


block diagram of 2 ups system connected in parallel mode?

2087


give me a clear defination of inductance,and how can u calculate inductance of a motor

2807


How to calculate the sag of OPGW during stringing???

2594


What is difference between SMC supportg and Glass Fibre Reinforced Plastic Support.

2352


. How to calculate the Short Circuit Impedance in Transformer? How to calculate the Short Circuit Impedance in Transformer?

2167


What is purpose of reactor?.What is different between line and bus reactor?

1956