difference between local breaker backup relay or backup protection relay ?
Answer Posted / k.prakashchandra
LBB relay is for failure of breaker to trip , and back up protection relay ( usually EM ) is for failure of main relay ( usually electronic )
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?
some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?
what is mean by drives?
do we use neutral grounding for resistive balanced load? if we use what happen?
what is difference between isolation and ultra isolation transformer?, what is the method of testing ?
The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?
why dc is used in control circuits for MV & LV switchgeras instead of ac
Give the expression for the frequency of oscillations in an op-amp sine wave oscillator?
What is icu and ics in Acb and how many time icu or ics passes from breaker?
For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?
either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...