Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to do manual mapping in radar type level transmitter?

Answer Posted / d chinna babu

Manual mapping will be done when radar gives wrong reading due to obstacles in reactor.For Eg if it is showing 15% level due to some obstacle the distance more than 15% should be entered in manual mapping to delete the error.
But mapping will not work for more than 20%

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks

2169


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1933


What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller

2356


In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.

1949


With N nodes and B branches what will have a network ???

2020


anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me

6024


where proximity sensor installed on tank in loading arm application

1943


Explain operation of Haskel pump.

2150


Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?

1786


give some question relative instrument fitter?

6260


Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com

2834


the 3 most common transmitter protocol being in refinery or qatar gas and aramco.

2930


What is intrinsically safe system?

1130


What is defferent betwen ESP &PCP PUMP .HOW IT IS WORK?

2468


Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor

2132