line safety is not opening but drum safety opens what to do?
Answer Posted / y v subba rao
Immediately we have to open the vent which was provided super heater outlet. The vent size should be such that it can draw sufficient steam from super heater to prevent overheating of coils due to starvation. We should keep it open till the minimum quantity of steam drawn by turbine. Mean while however drum safety will be closed due to pressure drop. Next we have proceed for line safety pressure setting.
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
why do you consider yourself a suitable candidate for this position
what is the basic use of power plant in equipment
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
By any way can we increase the B check hours from 300 to 500
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
what is the trip circuit supervision in an electrical meaning?
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
operation
can dp type level transmitter work in under vaccum condition
What is LB-SR.
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
what is the difference between compensated & normal drum level in boiler drum?
what does mean by kva rating
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.