State 5 different method of level measurements.

Answer Posted / usman

1 guage glass
2 dip stick
3 pressure transmitter (open tank)
4 diff pressure transmitter (close tank)
5 radar type
6 displacer type
7 ultra sonic waves
8 capacitance probes

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS THE CAM POSITION IN CONTROL VALVE POSITIONER ? WHY IT IS USED?

543


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

1832


How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1076


How can measure flow in oil line?which type of transmitter is generally used?

3536


What are the interlocks we have to check during the start up of LP/HP compressor?

1483






what is the usage of QDV & VOLUME BOOSTER

1772


Difference between ultra sonic flow meter

1547


How to Calibrate Level Troll in field

761


any questions on motor and energy conversions machines?

1774


What is 1:1 redundancy ?

1876


what is cold loop? difference between hot and cold loop?

1730


What is the difference between PLC and DDC?

1670


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1442


How we connect a instrument with ground, Give brief explanation with help of diagram?

1647


TEMPERATURE VARIATION FOR FREQUENTLY.

1507