What is purpose of APFC panel?

Answer Posted / rohitashsaini

Apfc full form is automatatic power factor control.in this way we use a control relay that we know apfc relay.such company provide this as neptune,bch,shreem,
c&S,trinty,epcos,syntron,sycon.this is work automatically when power factor is low set point.its reduce kva and reduced demand .formula is kwh/kvah.its reduce magnetic losses of systems that motor p.f is 0.8.and when u maintained p.f 0.95 to1.00 than utility pay u incentive.if u maintained 0.99 p.fthan electricity reduce 4% of ur total bill.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

17400


What is the role of power pack in substation protection system?

2223


WITCH CARDS IN USE IN FIRE CONTROL PANEL.

1454


diff b/w elcb and rccb

1840


what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?

4626






why in a swquence network representation, the negetive sequence generated voltage is taken as zero?

1502


I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.

1688


What is meant by earthhing of a magnetic flow meter and when to use empty pipe detection?

1697


What is purpose of reactor?.What is different between line and bus reactor?

1470


If you have an earth with pilecap then your resistance is really low. why and how?

1435


how load of a turbo generator can be increased

1464


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

1764


What is an order of a system.

722


how can i improve the power factor in domestic (230v)

1548


what is current check gurd relay?

2028