Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Answer Posted / kang chuen tat (malaysia - pen
Answer 13 : In the same state, total heat changes in heating = total heat changes in cooling for acetone. H = N ( total heat of sensible + heat of vaporization) = 100 (mol / s) [ (30.2) + (4.06 + 3.82) ] (kJ / mol) = 3808 kJ / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Can any one send me the sample test papers of IOCL entry exam to be held on 6th july 2008. Also plz send the interview questions that cud probably be asked........i wud be highly obliged if u can send a few test paers and other stuff @ inderjeetd@gmail.com.........Inderpreet
What is the maximum recommend pipe velocity for dry and wet gases?
How can you keep our seawater used for heat rejection clean before entering our heat exchangers?
Explain the method adopted to minimize shell side pressure drop in a shell?
What are the steps taken to operate a tank-blanketing valve?
What chemical is used to expand air bags in such a short amount of time?
How to caliculate the boil up rate, dia and height in both packed and tray distillation columns and any referance books for the design.
Why in a continuous plant for a Hot standby screw pump system the interlock for auto starting of the other pump ( when the running pump stopped suddenly) is given with header pressure only? why not with flow rate or current of the pump?
can anyone send me the written test paper of Indian oil corporation ltd. My email id is pratuljakhmola@yahoo.com
Explain what are some typical applications for glass-lined reactors?
Explain the method of determining maximum differential pressure during hydro testing of shell and tube heat exchangers?
How does a cyclone separator work?
What is the best way to control an oversized, horizontally oriented shell and tube steam heater?
What is the method involved in analyzing powders for composition?
In Galvonised iron and stainsteel pipes, in which pipe friction losses will more and why ?