Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Answer Posted / kang chuen tat (malaysia - pen
Answer 13 : In the same state, total heat changes in heating = total heat changes in cooling for acetone. H = N ( total heat of sensible + heat of vaporization) = 100 (mol / s) [ (30.2) + (4.06 + 3.82) ] (kJ / mol) = 3808 kJ / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
For what ration of Lengh/Dia. of tank (Jacketed tank), maximum heat transfer area is available?
What are the apt definitions for apparent power, active power and reactive power?
What is the maximum permissible Earth to Neutral voltage in an electrical system.
What are the methods involved to test helium leak testing in a vacuum system?
Why do we apply on iron articles?
What is a 'saltation velocity' and how is it used in designing pneumatic conveying systems?
What is a quick way to calculate frictional pressure drops in carbon steel pipe?
How much will be the increment for postal assistant yearly?
Explain what are some typical applications for glass-lined reactors?
How can metals be removed from aqueous waste streams?
Explain what are some common precipitating agents used to remove metals from aqueous waste streams?
What are the disadvantages of using gear pumps?
What are demand of crotonaldehyde99% in the worldand its international market ?
When an expansion is joint needed on the shell side of a shell and tube heat exchanger?
Which type of pneumatic control valve is used mostly Either Air to Open r Air to close the value And guys I need reason for your reason