Normally the
starter used to
reduce the
starting
current.but the
dol starter do not
it,so why we use
it?
Answer Posted / m s venkateswara rao
Normally Starters are used to reduce the starting current. But selection of the starter is based on the type of application whether starting torque is required high, medium, normal.Normally any motor during starting will take 4 to 5 times of full load current.Up to 10 Hp usually will use DOL because of motor full load current is 13 Amps and during starting will take 65 Amps as a result supply system dos not get affect. Above 10 HP usually motor full load currents are high and during starting will draw high starting current which will affect out supply system ie voltage drop, for which all associated equipment connected with the system will be affected.Usually above 10 HP motors with a application of medium torque will use star/ delta starter to reduce starting current. If the application is required high starting torque will use dol starter irrespective of the rating of the motor.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is difference between speed mode and torque mode in motor?? explain in simple words please.
Whether IP65 enclosure box blocks ventilation if driver for LED have to enclosed inside IP65 box
If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.
What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?
In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
What is Instantaneous Earth fault relay,how will work
what is alluminium arm in ab conductors
How we can change the direction of rotation of Induction motor? Prove it using graphical
being an electrical engineer why you wanna come into software i have an very good academics what answer i have to give
IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.
Why field rheostat is kept in minimum position?
1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done
What do you mean by power transformer?
Testing procedure of DG alternator stability test