what is mean by marshalling box in transformer?
Answer Posted / anubhav pandey
Maeshalling box is actually, a rectangular type box which consists of OTI (OIL TEMPERATURE INDICATOR), WTI (WATER TEMPERATURE INDCATOR). This inidcator indicates the current readings of Oil as well as Water. And, alarm is also associated in the respective box which start beeping when the specified temperature of water or oil exceeds or goes down. Various performance & monitoring could also be done with the help of this Marshalling box.
| Is This Answer Correct ? | 0 Yes | 11 No |
Post New Answer View All Answers
hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...
Tell me about ur past electrical maintanence job
Hi guys! Plz help me to answer the following questions. 1. What are the types of transmission line energy losses? 2. Why are the VLF are used some types of services? 3. What frequencies are used for reliable beyond the horizon terrestrial communication without repeaters? 4. To permit selection of 1 out 16 equi-probable, what is the number of bitis required? 5. What is the most common modulation used for telegraphy? 6. What is the multiplexing is used to increase the capacity of the optic fiber? Thanks
how to select correct size of power cable for inverter duty motor
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
Explain using drawings what is reverse PID action w.r.t PID controllers.
why steady state stability limit is greater than transient stability limit ? How it can be explained ?
Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com
What happen Grid EARTH plat got cut.
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?
How to set the relay,,??
Tell me in detail about c.t. And p.t. ?
Define the overload capacity of the motor?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions