If a HV Underground Cable (13.8KV) is layed in the ground below 1.5 Mtrs and any building construction is done on the Cable route. IS this allowable or Not? What should be the clearance. As per ISO construction on HV cable route is safe or Not? Why? Can any body suggest the site for my question?

Answer Posted / ra

cables for 13.8 kv is consider to be medium voltage (not HV ) and if it is routed in cable duct so there is no issue.the purpose of cable duct is to provided safety to cable route.
in case if the cable buried in ground, executor of building construction should notify the client through technical query to solve the issue by technical way according to specification and standard.
in my opinion builder suppose to keep opening for cable routing

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com

1553


PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM

1706


what is x'mer ,isolation x'mer & yltra-isolation x'mer?????

1831


Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?

1643


75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?

3259






What is meant by short-pitched winding?

647


Why syn. Generators are used for the production of electricity?

654


how to control the speed to switched reluctance motor

1481


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

1579


What is ST and specify its range of voltage.

1500


hii this is ranjith from hyd... i want to know what type of questions they ask in interview...and hw the interview will go..? what subjects thay ask specially for electrical engg students?

1494


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

650


i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?

3053


What are two contours of nichols chart?

619


what is the prinsiple of dc motor and construction and working ,application of dc motor.

1522