Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why VCB is required and ACB is also require?

what is the BDV of Trafo of 11/33 KV

Answer Posted / chander shekher

VCB & ACB are required for protection of electrical equipment/system.
VCB protects for over load, Earth Fault, Short Circuit,for HT Supply
whereas ACB are used for overload, earth fault & Short circuit for LT Supply

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to measure current and voltage in an ELV circuit

4135


please send me previous year questions of jspl through which i could prepare myself for the test.

1863


What is the difference between voltages or potential difference? And what are they?

1056


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

2010


How delta connection in the primary of distribution transformer reduces harmonics?how delta connections reduces harmonics?Please answer me...Hope that question is correct.

2191


How PADO software increase the efficiency of power plant?

6461


how many types of motor can be used in washing machine

2086


How good are you in resolving the commercial issues to Employer's advantage?

2344


what is magnetizing current test in power transformer

2725


star delta starter contorl circuit... drawing..

2059


What is the effect on in Zone and out zone fault if Phase side CT is Vk/2<30 mA and Neutral side is CT is Vk/4<30 mA for Transformer REF protection

3801


a 100mva,400/200v transformer has leakage impdce of 10% draws a steady state line currentof---------------

1893


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2265


What do you mean by Frame 5 Gas Turbine as well as Mark II.

2476


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2325