Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain Analog and Digital signals?

Answer Posted / kingshuk dey

Digital signals: They are wither ON or OFF state. That is 0 or 1. Like if a lamp is glowing or not.

Analog signal is a range of values that lie between ON and OFF. Like the position of gate between the "OPEN" and "CLOSE" position. Like, 45 degrees open. So the signal is between 4 to 20 mili-amps normally (4 amps is FULLY OPEN and 20 amps is FULLY CLOSED). 4 amps corresponding to 0% and 20 amps for 100%.

Is This Answer Correct ?    1 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why earthing is necessary for any equipment?

1782


STATE WORKING OF VACCUM CIRCUIT BRAKER?

1977


CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??

5710


how to protect motor in dol starter having capacity of 30 hp.40 hp?

3251


How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.

5444


The windings of a transformer are divided into several coils, because?

1332


What is the meaning of C1, C61, C91 cable

3525


How to select HT/MV cable size ?

2514


What do you mean by an instrument transformer?

1143


wat is the first thing dat is needed, 2 lay a cable in some area??

1917


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2364


why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?

1953


acb(AIR CIRCUIT BREAKER)NOT CHARGING AUTO

2450


Zone of protection and tripping scheme of arc protection relay.

1929


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1954