Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between ACB & MCCB?






Answer Posted / mohammed yousuf khan

ACB stands for Air Circuit Breaker whereas MCCB stands for Moulded Case Circuit Breaker. Generally MCCBs are used for loads upto 630A but if the load is higher say beyond 630A then the ACBs are used.

1)Also ACB is long lasting when compared to MCCB.

2)The switching contacts of ACB operate in air, whereas the switching contacts of MCCB operate in a case. Hence the name ACB & MCCB.

3)Apart from Overload, Short Circuit & Earth fault protection, other protections such as Under voltage protection can be achieved using ACB.

4)MCCBs are very compact, whereas ACBs are large in size when compared to MCCBs.

5)MCCBs needs to be replaced after a certain operations but ACBs can be re-used with little maintenance, as the spares are easily available for ACBs such as Contacts,arc chute etc...

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why CBCT rating is 50/1A

2924


What are the factors influence the choice of an electrc drive?

2119


If short circuit ratio is high is it bad or good for a machine then tell the reason...

2088


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1554


why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?

1564


what is mean by dual digital protection in the relay field?

1987


sir vizag steel ka junior trainee ka paper kitne number ka ayega

2309


if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer

1943


What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker

2057


What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?

1920


How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?

2557


what is earth-fault?when it occurs? to check where it occurs what type of test should we do?

2053


7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?

2325


where we use the SFU & FSU?

2466


how power trnafor from 1 point to another point in bus bar ya transmission line( voltage trnasfer from 1 point to another poin)

2052