Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why battery set is required for D.G.set?

Answer Posted / mukesh vaghela

we use DG set for generation of AC supply when AC supply is not available. We use DC supply of Battery for starting of DG SET only.....

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Generator,motor and alternator Working principal Please explain easily

1447


why we are not giving the zone 1 trip command to the master trip relay

1716


I am about to write exam in RRB bangalore for the post of section engineer.please provide me with previous exam questions

2131


When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?

2058


How do i carry out or know the vector group of a Dyn1 and Dyn5 transformer

2024


why chock were used in old tubelights but are not newest tubelights?

1931


How do we calculate the Out put voltage of generator, after the excitation is being given?

1908


What happens if the series current double?

1458


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

2285


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1661


HOW TO CALLICULATE RESITENCE,REACTANCE AND IMPEDENCE VOLTGE OF TRANSFORMER 13.33 KVA 144/240 VOLTS 93/56 A WITH FORMULA

1963


why we need to us lenz's law for synchornous motor

2550


What is the two pole structure?

1914


Why the magneti fields are not passes from southpole to north pole

2099


In EB metering we face problem kva jump even in no load condition.can any one help to control this

1818