Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Tan delta point in transformer to be earth or not?

Answer Posted / prem

Earthed.because core leakage current is tan delta point so earthed

Is This Answer Correct ?    3 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is different between Difnit time and instatous over current relay

2468


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1801


What is the difference between the transmission line and distribution line?

1114


What are the advantages & disadvantages of a group electrive drive?

2094


bsec exam syllabus (mis)

1221


why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?

1749


Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???

1928


If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?

5144


Is it true online ups having bypass mode if it is true then why we called ups because it is interrupting power when goes in bypass mode

1948


how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?

2076


How to test IR testing & magnetic balance test

1937


what is the standard duration after failure EB power

1776


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3585


what r PID controllers?why they r used?what is there purpose?plz Explain in detail

2028


Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet