IF i have switchgear with busbar current rating of 1000Amp
35kA then is it necessary to have outgoing breaker kA rating
to be equal to busbar kA rating?
Answer Posted / anil jangra
KA rating of any switchgear is depending on fault level of connecting load,so it necessary to calculate the fault current of load than select the switchgear rating,as per my opinion the must be able to clear the fault without damaging it self and healty one feeder also.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How a capacitor discharge weld power supply works? what is the use of a pulse transformer?
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?
What are the factor to be consider for CT selection in 132kV substation?
How we calculat the NGR of 3phase Generator, Our generation voltage 11KV
which of the following elements is not present in stainless steel
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
difference bewteen reverse current and alternating current
Write the force balance equation of ideal dashpot element.
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
How to calculate per unit impedance of transformer?
orifice sizing how done, checking & selection
how can i change the rotation of the AC single phase induction motor and show me by diagram
What do you mean by a current transformer?
Draw torque - speed curve and load curve of induction motor? mark operating point ?