why current transformer secondary is short circuited an what
will happen if connect very high resistance acrossthe
secondary side of current transformer?
Answer Posted / manan2347
In CT, high transient voltage will occur if secondary is not short circuited.
CT can withstand certain amount of burden not beyond that, if we connect more burden then CT's secondary can get damaged.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is error of a measurement?
Mention the difference between Analogue and Digital circuit?
How to measure size of cable on a given load
how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.
What will happen if i replace a inductive proximity switch with photo sensor in a machine?
For electrical designers what are the standard should know? i want learn about this standards. how to get information/reference. anybody help in this regards please.
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
1. Can a 12v DC choke operate a 60v/12w PL lamp ? 2. Can a 230v ballast fire / operate a 60v/12w PL lamps.
give me applications of sequence bridges . (used in 3 phase un balanced systems)
How to test Alternator stability test for REF relay
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
What is the importance of earthing?
how to revers the direction of single phase motor
CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??
how to calculate cooling requirement of datacentre from electrical load?