How to calculate the cement, sand quantity for plastering?
(10'x10')10mm thick ratio 1:5. wht"s the formula?
Answer Posted / shaik's construction
For a wall of 10'x10' ( i.e LxH) Having 10mm thicness
mortar ratio 1:6
10' approx equal to 3m
vol of mortar = 3*3*0.01
=0.09cum
vol of cement = 1*0.09/(1+6)
=0.01286cum :-(cement for 1cum=1440kg)
:-amount of cement=0.01286*1440
=18.5kg.
amount of sand=18.5*6=111kg
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
I want to know how much the lapping length for the pilecap reinforcement.. we r using single pile cap which is 24mby54m and 2.5m depth.. total 91piles are supporting the pile cap.. how to do a steel reinforcement??
Is it necessary to apply tack coat over the primecoat. IF not what happens.answers other than 1.to superimpose the next layer(2) to adhere the layers so as to form homogenity.
What is the density of most of construction materials?
does a b.tech civil engineer fresher supposed to know how to design rcc structure?
water leak detection system question & answer
what is smart building materials?
What is meant by dimensioning?
Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No. Loading Axial force Moment Shear 1 DL+LL 1950 600 20 2 Seismic load 250 4800 700
explain fie benefits of using standard terminology in the measurement process
hoe much fine & sourse agregate required for concrete mix of 1: 1.5:3 by volume in Cu.Ft
according to the painting co efficient, we should take the one side of doors (or) windows or both sides?
within an emergency scenario what are the safe systems of work a coss can setup as part of is duties
Use of coping on terrace wall and in 4" wall is compulsory or not ?
if a pipe those configuration (ASTM c 76 class b 450mm dia 2500mm length) fixing for water course those lining of water is 7000 running meter. my question is that if 8 joints of pipe ls leakage and we have not permission to stop the water so which treatment we apply on joint in that in condition.
What is the requirement for over all CG of DG from the foundation surface to absorb the vibration of heavy set.