When motor stater and roter air gap do big then what will moter.
Answer Posted / asit
larger air gap is equal to higher reluctance so lower reactance .so i=v/z(z=r+xl) so currnt will be high.thats why no load current in case of induction motor 20-30% of full load current as compare to transformer that is 2-5% of full load current
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
can we use engine degreaser for electrical motors?
What is the operating principle of turbo-generator.
Why saturation region slowly shifted in the left side?
what is a bus post insulator? explain its application in a substation.
Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?
how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence
How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.
i need some project topics along with circuit diagram in the electrical adnd electronics engg and also give ome website regarding projects.my mail id is thenmozhi2k7@gmail.com .please help me.
Define characteristics impedance?
What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.
Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me
what is the effect of earth on capacitance in 3-phase and 1- phase transmission line?
Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?
Explain the experiment on ward leonard method of a speed control on a dc shunt motor with an suitable circuit diagram.
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?