Which is the best protection in case of shortcircut fuses or mccb ?

Answer Posted / nur.asidik

it depends on voltage rating, current rating, and application, for motor, it is better to use fuse, why?. because we can select arcing current and arcing time.MCCB does not have. MCCB suitable only for static load

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is reverse power relay brief explanation and in b/w where it is connected

1485


i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.

3001


How to calculate VCB rating for 33KV ,25 MW Power line?

1225


how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???

1414


The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.

922






In siemens PLC, why do we want to move the data ?

1844


what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?

1486


need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.

1302


what is booster? and how it is connected in a circuit?

2013


What is the limitation of kirchoffs law?

636


How Diesel Generator start ?

1911


How to determine the breaking capacity such as break down current and break down voltage for VCB and CT's.

1729


What will happen if a dc source is given to a tubelight. Will it work or wont it work....

1478


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1436


how can i use REF and diffrencial relay both in 1 CT core for transformer protection?

1363