Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11

Answer Posted / sachin sharma...

generating voltage depends upon the total power capacity of the unit since for a low power gen. unit (e.g 126 MW ) lower armature insulation needed ,if we generate 11 kv, but if for a same unit gen. voltage is 33 kv then the it takes more armature insulation that increases the cost and size .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why did lightening arrestor solid copper rod head is sharp on mobile tower top?

1951


how to determine Sq.mm size of finolex power cables.

1940


what is the setting of locked rotor in HT motor ? (answer expecting in percentage)

2220


can i able to get bhel previous exam question paper?

2053


how to carried out DAR test in 11 KV Alternator ?

2250


1 hp is equal to how much watt?

1191


What is the lower limit of break-down voltage of converter transformer.

1856


how 650 volts creates? where is use?

2136


How to justify this statement ??? "Capacitors in series provide less capacitance but higher voltage breakdown rating for the combination"

1821


limitation of conductor height on ground when we consider EMC

1974


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1687


what is upper impedance and lower impedance of a distance relay

1975


what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?

4461


WHY RATING OF VCB NOT LESS THAN 630A

2565


What is pd controller?

1054