Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happenes if two voltage source connected in parallel
will be connected to load.

Answer Posted / ravivarma

voltage across the parallel circuits must be equal so its not possible to connect two sources in parallel to a load.

Is This Answer Correct ?    12 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1978


We have given to 3phase supply to ups system & how can coming netural

2157


What is knee point voltage of transformer?

1144


What happen in ups if phase reverse?

2295


What is the effect of positive feedback on stability of the system?

1659


What is meaning of out of phase (making & breaking) capacity And how to calculate

2253


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2746


Is there any type of starter for DC motor other than two point,Three point and Four point starters?

2044


How to calculate of maximum demand if given 628kw, 785kva, 0.8 p.f.

1661


what are the differant std sizes of cable trenches?

2061


When is lag lead compensator is required?

1124


What facility we get after CT secondary earthing and how?

2254


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1988


A 2083kva AVR was tested, phase to ground shows continuity, what is the implications

1033


3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........

1967