Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can we run 3 phase induction motor under 2 phase supply

Answer Posted / narendra patel

Yes we can operate 3 phase induction motor under 2 phase.
for the correct operation of 3 phase induction motor, we should have 3 phase with balance condition(i.e. 120 degree phase differance each other). if we have 2 phase with 120 degree phase differance then we can get another phase by connecting one capacitor with any of one phase. 
but it is risky that if we run for more time then the motor winding may heated up. and may it burn. because we does not have axact 120 degree phase shift..

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the relation between frequency and motor rpm?

1801


why are installed water leakage detection system data centers & server rooms

2303


description with working of all parts of a Diesel generator???????

2395


the winding of Generator and Motor is star or in delta ? and why

1055


what is the best method of grounding in 30 MW generator?

1969


Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

1005


Which device is used for the source of emission of electrons in a crt?

1206


sir i want previous entrance exam papers for written test

2080


When we giving the 3 phase supply to ups system how to coming netural?

2050


What are conduct on the testing in cf in ur site?

1608


Discuss the effect of sudden loading of an induction motor

1819


what is destructive and non-destructive testing of welding

1626


What is the two pole structure?

1862


IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.

1785


two phases with neutral supply can be taken in 3C X 10 sq.mm cable .

1370