Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happen if the battery is charged by more than one source ,for ex: connecting data cable to laptop & charger pin to source supply ? 

Answer Posted / nibel

actually the battery charger should deliver 10-20% more than the battery voltage rating. if its exceeds there will be the chances of explosion.
no need to worry about the polarity but the voltage rating matters.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate

2864


can we use trip light with bus coupler?

1985


Why the moulded plug comes with domestic appliances instead of assembled plug like anchor, Vinay 5/15 A.

2099


What will happen if i replace a inductive proximity switch with photo sensor in a machine?

1875


What is polar plot?

1240


Why reactors use before incoming of ac vvfd drive?

1908


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

2349


what r the checklist while installing a 380 kva DG set

3849


A car's starter motor draws a current of 100 A at 12,0 V when starting the engine. The mechanical power required to turn the engine is 960 W. At what rate is energy from the battery converted to non-mechanical forms of energy?

2200


why we used ZNO in Lightning arrester.

2047


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2148


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2253


What is signal flow graph?

1149


what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?

2000


we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?

1848