What is BMS (Building Managment System)& is AHU / HVAC are
in BMS.
Answer Posted / mohammed mujakar ( gulbarga, k
Dear Sathis,
First Look at Question i.e. What is BMS (Building Managment System)& is AHU / HVAC are in BMS. (not Burner Managment System)
BMS stands in diffrent form in diffrent feilds like BMS also stans for Buissiness Management System so on.
Ans:
Building Managment System is a Automated Controlled based system which instaled in Building/Shopping mall/ Buisness Centre etc. to Operate ,Controll and Monitore the
buildings Electrical and Mechanicle Equipment including Fire Alarm system, Access control, CCTV systems, Boilers trough monitoring system (Personel Comuter).
| Is This Answer Correct ? | 28 Yes | 2 No |
Post New Answer View All Answers
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
how to measure oxygen which methods are using?
what is cold loop? difference between hot and cold loop?
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
what is output of FOUNDATION FIELD BUS transmitter
what is effect of specific gravity in differential level transmitter , explain formula related with this .
what is the different between deflection type measurement and null type measurement in RTD?
How hart protocol can be connected with control valves?
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
selection of the zener barrier for the hazardeous area zone 0
what is instrument philosophy
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
how pressurize drum calibrated ?
what deference between panel earth and systemearth