Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to calculate the current carrying capacity of a 25 & 16
kva distribution transformer.

Answer Posted / nagarjun

Apply 1.732*v*i*cospi.. We hv to know Wt the supply voltage is..

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how generator load test is conducted?what are the steps?

1554


What kind of socket shall be provided for window type air conditioner with cooling capacity upto 18000 BTU/hr

1021


what is (+) and (-) in generator field detector stand for?

1782


How many types of protection relays are there based on the characteristic?

1022


What are the two segments of nyquist contour.

1044


which connection is safer series or parallel?usually which connection we prefer at home?

9798


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1855


why we used dc supply for field in dg set

2336


why electronic instruments is more favorable than electrical?

1915


How to Design green buildings services? What is the advantage to design green building?

1747


What is the bundle conductor?

1143


Is MEN and RCD related to each other ?? IF yes then how??

1826


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


what is sevice settings for mccb?How can be it setted?

2129


explain safety measures in alternator?

1712