I have a close vessel tank which is under vaccum when in running condition so pl. Provide it's range for dp type tx whose flange to flange distance is 440 mm and density is 1
Answer Posted / carl_ellis
A closed pressure vessel requires a differential pressure
measurement in order to compensate for the pressure or
vacuum in the vapor space above the liquid.
The density is said to be 1, so we'll assume that what was
really meant is that the specific gravity is 1.00, the same
as the specific gravity of water. The measurement can be
made in engineering units of mm of water column (wc) with no
compensation for a specific gravity other than water.
A DP transmitter measurement:
(high side pressure) minus (low side pressure)
The low side pressure reading is (vacuum pressure).
The high side pressure reading is (column of water pressure
+ vacuum pressure)
(water column pressure + vacuum pressure) minus vacuum
pressure = water column pressure.
With a vertical elevation difference between the flanges of
440mm, the water column pressure will be
0 - 440mm wc.
LRV = 0.0 mm wc
URV = 440 mm wc
Carl Ellis
Measure First
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?
I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?
we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?
What is motion balance principle?
Tr. Wiring for calibration.
Explain the difference between mmwc and mmwg?
Please asked me How calculate DCS controller memory.
What is loop1 and loop2 in MTS LT?
NSV type probe stands for
whats the abbreviation of IOP? is it instrument of power or input open problem?
how to convert cubic metre per hour to newton cubic metre per hour
principle of automatic votage regulator
How ejector(or)evactor air pump is working in thermal power plant?
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com